Overview
- For water, glycol solutions and coolants
- Inline device with DN 10 internal diameter and G3/2 external thread
- integrated PT1000 element measures the temperature of the medium
- Flow and temperature are output as an analogue signal 4...20 mA
- Protection rating IP65
Description
AS007 is an inexpensive and excellent way to measure flow rates and temperatures in pipes. The measuring range extends from 1.8 to 32.0 l/min for liquid water-based media. A PT1000 element measures the temperature between -25°C and +125°C. The measurements are output as a 4...20 mA signal. The sensor is installed as an inline device with a DN 10 internal diameter and a G ¾ external thread between two pipes. The vortex measuring principle uses vortices whose frequency is proportional to the flow velocity. The measuring principle is not susceptible to soiling and is also suitable for non-conductive water, something that is not possible with magnetic-inductive methods. AS007 can be used for cooling water, hot water and drinking water applications. The sensor is ideal for heating and cooling circuits. Its simple connection and space-saving design allow installation in confined spaces.
Technical data AS007
General information
water; glycol solutions; coolants
1.8 ... 32 l/min
-25 °C
125 °C
1.8 ... 32 l/min
-25 °C
125 °C
Outputs / inputs
4 ... 20 mA
2 x
When used with an analog output use exclusively sensor cables without LED
Water [4...20 mA]: Q [l/min] = 2,0 x (I - 4 mA)
Temperature [4...20 mA]: T [°C] = 9,375 x (I - 4 mA) - 25
2 x
When used with an analog output use exclusively sensor cables without LED
Water [4...20 mA]: Q [l/min] = 2,0 x (I - 4 mA)
Temperature [4...20 mA]: T [°C] = 9,375 x (I - 4 mA) - 25
Electrical data
10 ... 33 V DC
Direct voltage (DC)
PNP
III
Yes
Direct voltage (DC)
PNP
III
Yes
Mechanical data
EPDM
ETFE
PA 6T
12 Nm
ETFE
M12
3-pin
Contacts gold-plated
12 bar (up to 40 °C)
Flat sealing
DN10
External thread
G 3/4
ETFE
PA 6T
12 Nm
ETFE
M12
3-pin
Contacts gold-plated
12 bar (up to 40 °C)
Flat sealing
DN10
External thread
G 3/4
Accuracy
± 0.2% MREV * (flow monitoring)
Q < 50 % MEW: < 1 % MEW / Q > 50 % MEW: < 2 % MW; (water) | ± 0,5 °C ± 0,005 x ΔT
* MV = measured value, MREV = measurement range end value
< 2 s
0.5 s (flow monitoring
Q < 50 % MEW: < 1 % MEW / Q > 50 % MEW: < 2 % MW; (water) | ± 0,5 °C ± 0,005 x ΔT
* MV = measured value, MREV = measurement range end value
< 2 s
0.5 s (flow monitoring
Ambient conditions
-15 °C
85 °C
P(absolute) discharge / P(difference) > 5.5 to avoid cavitation
IP65
85 °C
P(absolute) discharge / P(difference) > 5.5 to avoid cavitation
IP65
Additional information
380 years
No accessories included
EN 61326-2-3
DIN EN 60068-2-27
DIN EN 60068-2-6
Sound Engineering Practice; can be used for group 2 fluids
CE
KTW / W270
No accessories included
EN 61326-2-3
DIN EN 60068-2-27
DIN EN 60068-2-6
Sound Engineering Practice; can be used for group 2 fluids
CE
KTW / W270
Drawings
dP: Pressure loss
Q: Volumetric flow quantity
Q: volumetric flow quantity
T: temperature
Pin 1 & Pin 4 supply sensor with current; analog output on pin 2 is optional
Downloads
Data sheet Customer reviews