Overview
- For water, glycol solutions and coolants
- Inline device with DN 32 internal diameter and G1 1/2 external thread
- Robust brass body 100% lead-free - also suitable for drinking water applications
- Flow and temperature are output as an analogue signal 4...20 mA
- Protection rating IP65
Description
The AS011 is an inexpensive and excellent way to measure flow rates and temperature in pipelines. The sensor is installed as an inline device (DN32) between two pipes with G1 ½ connection. The sensor enables flow measurement with very good accuracy - independent of temperature changes. The measuring range is between 14 and 240 l/min. A temperature measurement between -25°C and +125°C is also integrated. Both measured variables are output as a 4...20 mA signal.The vortex measuring principle uses turbulence whose frequency is proportional to the flow velocity. The measuring element is insensitive to dirt and is suitable, among other things, for water without conductivity, which is not possible with magnetic-inductive methods. Typical applications are heating and cooling circuits. The extremely robust brass housing is manufactured completely lead-free and is therefore suitable for drinking water requirements.
Technical data AS011
General information
water; glycol solutions; coolants
14.0 … 240 l/min
-25 °C
125 °C
14.0 … 240 l/min
-25 °C
125 °C
Outputs / inputs
4 ... 20 mA
2 x
When used with an analog output use exclusively sensor cables without LED
Temperature [4...20 mA]: T [°C] = 9,375 x (I - 4 mA) - 25
Water [4...20 mA]: Q [l/min] = 15.000 x (I - 4 mA)
No
2 x
When used with an analog output use exclusively sensor cables without LED
Temperature [4...20 mA]: T [°C] = 9,375 x (I - 4 mA) - 25
Water [4...20 mA]: Q [l/min] = 15.000 x (I - 4 mA)
No
Electrical data
10 ... 33 V DC
Direct voltage (DC)
III
Yes
Yes
Direct voltage (DC)
III
Yes
Yes
Mechanical data
EPDM
Brass
ETFE
Brass
PA 6T
M12
3-pin
Contacts gold-plated
12 bar (up to 40 °C)
Flat sealing
DN32
G 1 1/2
External thread
Brass
ETFE
Brass
PA 6T
M12
3-pin
Contacts gold-plated
12 bar (up to 40 °C)
Flat sealing
DN32
G 1 1/2
External thread
Accuracy
± 0.2% MREV * (flow monitoring)
Q < 50 % MEW: < 1 % MEW / Q > 50 % MEW: < 2 % MW; (water) | ± 0,5 °C ± 0,005 x ΔT
* MV = measured value, MREV = measurement range end value
< 2 s
0.5 s (flow monitoring
Q < 50 % MEW: < 1 % MEW / Q > 50 % MEW: < 2 % MW; (water) | ± 0,5 °C ± 0,005 x ΔT
* MV = measured value, MREV = measurement range end value
< 2 s
0.5 s (flow monitoring
Ambient conditions
-15 °C
65 °C
P(absolute) discharge / P(difference) > 5.5 to avoid cavitation
IP65
65 °C
P(absolute) discharge / P(difference) > 5.5 to avoid cavitation
IP65
Additional information
380 years
No accessories included
EN 61326-2-3
DIN EN 60068-2-27
DIN EN 60068-2-6
Sound Engineering Practice; can be used for group 2 fluids
CE
KTW / W270
No accessories included
EN 61326-2-3
DIN EN 60068-2-27
DIN EN 60068-2-6
Sound Engineering Practice; can be used for group 2 fluids
CE
KTW / W270
Drawings
dP: Pressure loss
Q: Volumetric flow quantity
Q: volumetric flow quantity
T: temperature
Pin 1 & Pin 4 supply sensor with current; analog output on pin 2 is optional
Downloads
Data sheet Customer reviews