Overview
- Response sensitivity 2.1 mT
- Travel speed >10 m/s
- ideally suited for applications in packaging/handling and special machine construction
- Self-locking fixture for easy mounting and adjustment and particularly fast and safe commissioning due to 3-wire connection technology
- Various mounting options on different cylinder types thanks to our adapter range
Description
The AZ005 reed contact cylinder sensor is suitable for most common T-slots. It is simply dropped from the top into the slot and installed quickly and easily with a self-locking fixture. The AZ005 provides very high switching frequencies and can be used for applications with high load currents thanks to the three-wire connection. Electrical connection is via a 30 cm pigtail (3x 0.14 mm² PUR cable) with an M12 connector. With a response sensitivity of 2.1 mT and a travel speed of 10 m/s, our cylinder sensors are ideally suited for applications in packaging, handling and special machine construction.The cylinder sensor is suitable for both direct current and alternating current. Please note that safe operation can only be guaranteed with a miniature fuse in accordance with IEC60127-2 Sheet 1 (= 0.75 A fast DC operation, = 0.6 A fast AC operation). The operating voltage is between 5...50 AC/DC and an external protective circuit for inductive loads (valve, contactor, etc.) is necessary.
Our wide range of adapters enables connection to various cylinder types. Installation accessories and further information can be found further down on the item page.
Technical data AZ005
General information
Reed-Contact
1000 Hz
1000 Hz
Outputs / inputs
Normally open (NO)
Electrical data
Miniature fuse to IEC60127-2 sheet 1; ≤ 0,75 A; fast acting; DC operation; ≤ 0,6 A; fast acting; AC operation
10 W
5...50 V AC/DC; (External protective circuit for inductive load (valve, contactor, etc.) necessary.; "supply class 2" to cULus)
Direct voltage (DC)
Alternating voltage (AC)
PNP
DC: 500 mA / AC: 350 mA
1 V
III
No
No
No
10 W
5...50 V AC/DC; (External protective circuit for inductive load (valve, contactor, etc.) necessary.; "supply class 2" to cULus)
Direct voltage (DC)
Alternating voltage (AC)
PNP
DC: 500 mA / AC: 350 mA
1 V
III
No
No
No
Mechanical data
Stainless steel
Cuboid
Flush
30.5 mm
PA
M12
3-pin
Contacts gold-plated
PUR
0.3 m
Cuboid
Flush
30.5 mm
PA
M12
3-pin
Contacts gold-plated
PUR
0.3 m
Accuracy
1 mm
2,1 mT
< 0.2 mm
> 10 m/s
0.1 ms
0.6 ms
2,1 mT
< 0.2 mm
> 10 m/s
0.1 ms
0.6 ms
Ambient conditions
-25 °C
70 °C
IP65
IP67
70 °C
IP65
IP67
Additional information
20385 years
Switching status: LED, yellow
1 rubber placeholder
1 cable clip
DIN EN 55011: Class B
DIN EN 61000-4-2 ESD
DIN EN 61000-4-3 HF radiated
DIN EN 61000-4-4 burst
DIN EN 61000-4-6 HF grid-bound
CE
cULus
Switching status: LED, yellow
1 rubber placeholder
1 cable clip
DIN EN 55011: Class B
DIN EN 61000-4-2 ESD
DIN EN 61000-4-3 HF radiated
DIN EN 61000-4-4 burst
DIN EN 61000-4-6 HF grid-bound
CE
cULus
Drawings
L: 0.3 m
1: Fastening clamp
2: sensing face
Note miniature fuse to IEC60127-2 sheet 1
≤ 0.75 A fast acting DC operation
≤ 0.6 A fast acting AC operation
Downloads
Data sheet Customer reviews