AF907Level probe potable water 0…0.2 bar 4…20 mA
NET PRICE (plus VAT)
229.03 €
Offline: 242.36 €
GROSS PRICE (incl. VAT)
272.54 €
Offline: 288.40 €
Incl. 5.50 % online discount
30 in stock!
Overview
- Hydrostatic level probe for continuous measurement
- Suitable for drinking water applications (KTW approval)
- Measuring range: 0...0.2 bar / 0...2 m H2O
- Analogue output with 4...20 mA signal
- Fixed 10 m connection cable
- For level measurement in tanks, containers and basins
Description
The AF907 level probe is designed for continuous hydrostatic level measurement in tanks and vessels. With its KTW approval, it is officially suitable for use in drinking water applications, ensuring safety and compliance in sensitive environments.
This probe operates within a measuring range of 0 to 0.2 bar, corresponding to a water column of 0 to 2 meters. It provides a standardized 4...20 mA analog output signal for reliable integration into control systems. The unit is supplied with a 10-meter cable, allowing for flexible installation in various depths.
- Precise hydrostatic measurement for continuous level monitoring.
- Measuring range of 0...0.2 bar / 0...2 m H2O.
- Approved for drinking water applications (KTW certification).
- Industry-standard 4...20 mA output for easy integration.
- Ideal for use in the water industry, pumping stations, or rainwater overflow basins.
- Features a 10 m connection cable for installation flexibility.
Technical data AF907
General information
Water, water-based media, suitable for drinking water
Immerge level transmitter with cable to the ground;
Level probe
Immerge level transmitter with cable to the ground;
Level probe
Outputs / inputs
4 ... 20 mA
No
No
Electrical data
10 ... 30 V DC
Direct voltage (DC)
20 mA
< (supply voltage - 7 V) / 0.02 A
III
Yes
Yes
Direct voltage (DC)
20 mA
< (supply voltage - 7 V) / 0.02 A
III
Yes
Yes
Mechanical data
V4A (1.4404)
FPM
Al2O3 (ceramic)
PE-HD
Al2O3 (ceramic)
PPE
V4A (1.4404)
FPM
10 m
PE-HD
FPM
Al2O3 (ceramic)
PE-HD
Al2O3 (ceramic)
PPE
V4A (1.4404)
FPM
10 m
PE-HD
Accuracy
± 0.3 % FS*
± 1% FS *
± 0.5 % FS* / 10K
± 0.25 % FS*
*FS: Fullscale
± 1% FS *
± 0.5 % FS* / 10K
± 0.25 % FS*
*FS: Fullscale
Ambient conditions
3 bar
-20 ... 80 °C °C
IP68
-20 ... 80 °C °C
IP68
Additional information
1 protection cover
1 protective filter for the ventilation pipe
CE
cULus
90262020
0.2 kg
CH
1 protective filter for the ventilation pipe
CE
cULus
90262020
0.2 kg
CH
Drawings


CASE = case grounding
Downloads
Data sheet 