  • Temperature sensor with factory-set measuring range -50...150 °C and G1/2 process connection with external thread, M12 connector (4-pin) and analogue output
  • PT1000 measuring element according to DIN EN 60751, Class A
  • with IO-Link interface
  • suitable for use with liquid and gaseous media
  • Protection rating IP67/ IP68/ IP69k

Description

The AT003 temperature transmitter with a factory-set measuring range from -50 ... 150 °C has a G 1/2 process connection, an analogue output and a PT 1000 measuring element to DIN EN 60751, class A. The unit has an installation depth of 30 mm, an M12 connector and an IO-Link interface.

Suitable for liquids and gases

Temperature monitoring is one of the most important measurement tasks in automation and process technology. The correct temperature often influences the quality and efficiency of the corresponding processes.

Tried-and-tested millions of times in daily use. Temperature transmitters from autosen are manufactured according to the highest quality standards with regard to robustness, noise immunity and reliability. We offer you a 5-year warranty for our product – with money-back guarantee!

Note: When used with an analogue output use exclusively sensor cables without LED.

If you have questions regarding the IO-Link parameterization or want to use the parameterization service of autosen, please do not hesitate to contact us. Or start directly with the IO-Link starter kit ADS01.

Technical data AT003

General information

Liquid and gaseous media
400 bar
-50 °C
150 °C

Outputs / inputs

4 ... 20 mA
Programmable
Scalable
When used with an analog output use exclusively sensor cables without LED
Yes

Electrical data

18 ... 32 V DC supply class 2 cULus
Direct voltage (DC)
PNP
50 mA
III
Yes
Yes
Yes
1 s

Mechanical data

V4A (1.4404)
FKM
6 mm
LCP
PEI
V4A (1.4404)
PTFE
PC
V2A (1.4310)
M12
4-pin
Contacts gold-plated
External thread
G 1/2
30 mm

Accuracy

1 s / 3 s
< ± 0.5 °C

Ambient conditions

-25 °C
80 °C
IP67
IP68
IP69k

Additional information

572 years
LED
Green
Seal
DIN EN 61000-4-2 ESD
DIN EN 61000-4-3 HF radiated
DIN EN 61000-4-4 burst
DIN EN 61000-4-5 surge
DIN EN 61000-4-6 HF grid-bound
DIN IEC 68-2-27
DIN IEC 68-2-6
CE
cULus