Overview
- For liquid and gaseous media
- 0..400 bar
- Analogue output
- with IO-Link, 4-digit alphanumeric display and alternating display in red/green
- ceramic-capacitive pressure sensing element
Description
The electronic pressure sensor AP020 was designed for industrial applications and has a firmly set measuring range from 0 ... 400 bar. The unit has an analogue output, a G 1/4 male process connection (to DIN EN ISO 1179-2) and an M12 connector.Suited for group 2 fluids according to the Pressure Equipment Directive (PED).
Pressure sensors from autosen have robust housings and do not require moving parts such as pistons or springs. The result: The sensors are extremely shock and vibration resistant and operate without any wear or maintenance. Our sensors are resistant to dynamic pressure peaks and guarantee high overload resistance even in the case of extreme pressure peaks that occur for example with fast closing valves.
Tried-and-tested millions of times in daily use. Electronic pressure sensors from autosen are manufactured according to the highest quality standards with regard to robustness, noise immunity and reliability. We offer you a 5-year warranty for our product – with money-back guarantee!
Note: When used with an analogue output use exclusively sensor cables without LED.
Technical data AP020
General information
Liquid and gaseous media
0 bar
400 bar
1700 bar
1000 bar
External thread
G 1/4
0 bar
400 bar
1700 bar
1000 bar
External thread
G 1/4
Outputs / inputs
4 ... 20 mA
No
No
Electrical data
8.5 ... 36 V DC
Direct voltage (DC)
PNP
III
Yes
Yes
Yes
Direct voltage (DC)
PNP
III
Yes
Yes
Yes
Mechanical data
FKM
V4A (1.4542)
V4A (1.4542)
PEI
V4A (1.4404)
FKM
V4A (1.4542)
M12
2-pin
Contacts gold-plated
V4A (1.4542)
V4A (1.4542)
PEI
V4A (1.4404)
FKM
V4A (1.4542)
M12
2-pin
Contacts gold-plated
Accuracy
< ± 0.2 %
< ± 0.05%
< ± 0.05%
Ambient conditions
-40 °C
90 °C
IP67
IP69k
90 °C
IP67
IP69k
Additional information
686 years
No accessories included
DIN EN 61000-6-2
DIN EN 61000-6-3
DIN EN 60068-2-27
DIN EN 60068-2-6
CE
cULus
No accessories included
DIN EN 61000-6-2
DIN EN 61000-6-3
DIN EN 60068-2-27
DIN EN 60068-2-6
CE
cULus
Drawings
1: Process connection sealing FKM / DIN 3869
OUT: analogue output 4 ... 20 mA
Downloads
Data sheet Customer reviews